Complete System

Null Kelvin referansesystem

Zero-Point var fortsatt over null.

$389,000
Null Kelvin referansesystem

Nøkkelfunksjoner

  • Complete superconducting signal chain: power, clock, digital, analog, and speaker
  • Zero total DC resistance from wall outlet to speaker driver
  • Meissner effect across every cable run — entire system is magnetically null
  • 500L central LN2 reservoir with 12-port distribution manifold
  • 24-sensor monitoring array: temperature, pressure, O2 depletion, flow rate
  • Touchscreen HMI with Ethernet remote monitoring and alarm notification
  • First year of liquid nitrogen included (~5,840 liters)
  • 3-day professional installation by certified cryo-technician
  • Structural floor assessment and reinforcement consultation
  • Emergency oxygen depletion alarm system with automatic ventilation trigger
  • Annual maintenance program available (reservoir inspection, valve service, sensor calibration)

Spesifikasjoner

Inkluderte kabler 4× SC Power (2m), 1× SC Digital (1.5m), 1× SC Clock (1.5m), 2× SC Interconnect (1.5m), 1× SC Speaker Pair (3m)
LN2-reservoir 500L vacuum-insulated, stainless steel
Fordelingsror 12-port, individually valved, cryo-rated
Overvåkingsarray 24 sensors (temperature, pressure, O2, flow rate)
Kontrollsystem Touchscreen HMI with remote monitoring via Ethernet
Total DC Resistance 0.000000 Ω (entire signal chain)
Magnetisk skjerming Meissner effect across all cable runs simultaneously
First-Year LN2 Included (~5,840 liters)
Annual LN2 (subsequent) ~$5,840/year (consumption varies with ambient temperature)
Installasjon 3-day on-site by certified cryo-technician
Total systemvekt > 1,000 kg (filled)
Stromkrav Dedicated 30A circuit for monitoring and reservoir heater
Romkrav Ventilation ≥ 10 ACH, O2 monitoring, emergency shut-off
Gulvkrav Structural assessment mandatory (>1 tonne point load)
Garanti 5 years (cables), 3 years (reservoir and manifold), 2 years (monitoring)

Komplett supraledende signalkjede. Fire SC strømkabler, ett klokkekabel, ett digitalkabel, to interconnects, ett par høyttalerkabler. Null motstand fra vegg til høyttaler. 500-liters LN2-tank. Ca. 5 840 liter per år. Over ett tonn. Gulvvurdering obligatorisk.

Liten skrift

  • * Requires dedicated 30A electrical circuit. Room ventilation rate ≥ 10 air changes per hour mandatory. Structural engineering assessment of floor mandatory prior to installation. Local building permits may be required. First-year LN2 consumption estimate based on 22°C ambient; actual consumption varies. Subsequent years' LN2 not included. Installation date subject to cryo-technician availability. Results in non-equatorial environments may vary.